The Yokogawa A2LP131-S00 is a specialized PROFINET IO-Controller communication module designed for CENTUM VP integrated production control systems. Operating as a master controller, it exchanges process data and alarm notifications with PROFINET IO-Devices at 100 Mbps via an IEEE 802.3 100BASE-TX RJ-45 port.
Seamless Integration of Industrial Ethernet with DCS Architectures
In continuous process and hybrid automation industries, connecting modern field smart instruments and subsystem controllers to a central Distributed Control System (DCS) requires fast, standardized communication protocols. The Yokogawa A2LP131-S00 PROFINET Communication Module acts as an advanced PROFINET IO-Controller within the Yokogawa CENTUM VP platform. Installed directly into Field Control Stations (FCS) or expansion ESB node units, the module establishes high-speed 100 Mbps data exchange with field PROFINET IO-Devices, bringing field-level diagnostic and measurement data into central control function blocks.
Certified Compliance and Robust System Capabilities
The A2LP131-S00 module is officially certified to comply with PROFINET Specification Version 2.35 Conformance Class A (CC-A), while also supporting CC-B and CC-C devices within the CC-A functional scope. Each module features a single IEEE 802.3 100BASE-TX physical interface using a standard RJ-45 connector and 2×2 twisted-pair shielded cabling over segment distances up to 100 meters.
With an I/O communication data capacity of 1000 words per module and support for up to 128 connectable PROFINET IO-Devices, the A2LP131-S00 allows control engineers to map data types—including Boolean, Integer16/32, Unsigned16/32, and Float32—directly into CENTUM VP regulatory and sequence control function blocks.
Alarm Handling, Network Redundancy, and Modular Design
Beyond standard cyclic data transmission, the A2LP131-S00 actively processes alarm messages generated by field IO-Devices and routes notifications instantly to the Field Control Unit (FCU). In high-availability architectures, the module supports PROFINET network communication path dual redundancy when configured with managed switches running Media Redundancy Protocol (MRP) in a ring topology.
Compact and lightweight at approximately 0.31 kg, the module measures 32.8 mm in width, 125.5 mm in depth, and 130 mm in height. It operates on a maximum current consumption of 0.8 A, maintaining low thermal output in control cabinets.
Applications
-
Distributed Control Systems (DCS): Integration of field-level PROFINET IO-Devices into Yokogawa CENTUM VP control station architectures.
-
Oil & Gas Processing: High-speed Ethernet interfacing with motor management systems, flow skids, and smart instrumentation.
-
Chemical & Petrochemical Operations: Real-time data exchange between central control units and packaged reactor or dosing skids.
-
Power Generation Facilities: Field bus communication with turbine control auxiliaries and electrical protection relays.
-
Water & Wastewater Utilities: Centralized monitoring of remote pumping stations and analytical equipment over industrial Ethernet.
Technical Specifications
-
Manufacturer: Yokogawa
-
Product Model: A2LP131-S00
-
Product Type: PROFINET Communication Module (for N-IO/FIO)
-
Role: PROFINET IO-Controller
-
PROFINET Certification: Version 2.35 Conformance Class A (CC-A)
-
Physical Layer Interface: IEEE 802.3 100BASE-TX
-
Connector Type: RJ-45 (1 physical port)
-
Transmission Speed: 100 Mbps
-
Transmission Cable & Distance: 2×2 twisted-pair shielded cable, max. 100 m per segment
-
Max. Connectable Devices: Up to 128 PROFINET IO-Devices per module
-
I/O Data Capacity: 1000 words per module
-
Maximum Current Consumption: 0.8 A
-
Module Weight: Approx. 0.31 kg
-
Dimensions (W x D x H): 32.8 mm x 125.5 mm x 130 mm
-
Compatible FCS Models: AFV30S, AFV30D, AFV40S, AFV40D, A2FV50S, A2FV50D, A2FV70S, A2FV70D
-
Compatible Node Units: ANB10D, ANB10S, ANB11D, ANB11S
FAQ
Q1: What is the primary function of the Yokogawa A2LP131-S00 module? A: The A2LP131-S00 acts as a PROFINET IO-Controller master module in Yokogawa CENTUM VP systems, exchanging process data and alarms with field PROFINET IO-Devices.
Q2: What is the exact module weight and dimensions of the A2LP131-S00? A: According to Yokogawa specification sheet GS 33J60G90-01EN, the module weighs approximately 0.31 kg and measures 32.8 mm (W) x 125.5 mm (D) x 130 mm (H).
Q3: How many PROFINET IO-Devices can a single A2LP131-S00 module support? A: A single A2LP131-S00 module supports up to 128 connectable PROFINET IO-Devices with a maximum communication I/O data capacity of 1000 words.
Q4: Which CENTUM VP software revisions support the A2LP131 module? A: The module requires CENTUM VP R6.07 or later, using control functions VP6F1700, VP6F1800, or VP6F1900 along with engineering tool VP6E5100.
مستندات المنتج
فتح المستندات الفنية.
أدخل بريد العمل ورقم واتساب مرة واحدة للوصول إلى جميع المستندات.