المنتج
YOKOGAWA SDV144-S53/B4S00 Digital Input Module
SDV144-S53/B4S00 Module
The YOKOGAWA SDV144-S53/B4S00 is a 16-channel digital input module designed for contact signal acquisition in ProSafe-RS safety instrumented systems. It features module isolation, ISA Standard G3 corrosive gas resistance, and an included pressure clamp terminal block for secure industrial field wiring.
Product Overview
The YOKOGAWA SDV144-S53/B4S00 is an advanced 16-channel Digital Input Module engineered specifically for Yokogawa’s ProSafe-RS safety instrumented system architecture. Designed to accept contact signals from field devices, this module acts as a critical interface node in safety control and emergency shutdown (ESD) loops. The S53 suffix configuration incorporates standard non-explosion protection, a pressure clamp terminal block connection interface, ISA Standard G3 corrosive gas resistance, and an extended operating temperature range of -20°C to +70°C. Furthermore, the /B4S00 option code supplies a dedicated pressure clamp terminal block for digital input (Model STB4S-00, without surge absorber), providing a complete and ready-to-install hardware solution.
Key Features & Highlights
-
ProSafe-RS Safety Integration: Built explicitly for high-integrity safety instrumented systems, ensuring reliable signal processing in safety-critical control loops.
-
16-Channel Module Isolation: Features 16 independent input channels with module isolation, protecting system logic from field-side electrical disturbances.
-
Included Pressure Clamp Terminal: Supplied with an integrated pressure clamp terminal block (Model STB4S-00 without surge absorber) for secure, vibration-resistant field wire termination.
-
Environmental Hardening: Manufactured with built-in ISA Standard G3 compliance and wide temperature tolerance (-20°C to +70°C) for rigorous industrial plant environments.
-
Transmitter and Contact Compatibility: Designed to support no-voltage contact inputs and 2-wire transmitters with external 24 V DC power supply requirements.
-
Compact and Lightweight Build: Designed with a space-saving width of 32.8 mm and an approximate weight of 0.38 kg, minimizing physical backplane stress inside control cabinets.
Functional Architecture
The SDV144-S53/B4S00 operates on a 24 V DC external power supply with a 6 mA input current specification. It supports no-voltage contact inputs (ON state at 1 kilo-ohm maximum, OFF state at 100 kilo-ohms minimum) with a rapid maximum response time of 40 ms. Built-in withstand voltage protection (2 kV AC between input signal and system) ensures stable operation under fluctuating industrial electrical conditions.
Application
-
Oil & Gas Upstream & Downstream: Emergency shutdown systems (ESD), fire & gas monitoring, and offshore platform safety loops.
-
Petrochemical & Chemical Plants: High-integrity digital interlock and safety instrumented protection systems.
-
Power Generation Facilities: Boiler safety interlocks, turbine protection, and critical trip logic networks.
-
Water & Wastewater Management: Critical digital alarm monitoring and automated safety shutdown infrastructure.
Technical Specifications
| Item / Feature | Specification Details |
| Model & Suffix Code | SDV144-S53/B4S00 |
| Module Type | Digital Input Module (16-channel, 24 V DC, module isolation) |
| Number of Inputs | 16 channels, module isolation |
| Input Signal Type | No-voltage contact (ON: 1 kilo-ohm max, OFF: 100 kilo-ohms min) |
| Input Current | 6 mA +/- 20% (External power supply, 24 V DC at 0 ohm input) |
| Contact Rating | 24 V DC +20% / -10%, 10 mA or greater |
| External Power Supply | 24 V DC +20% / -10% (Current capacity: 200 mA) |
| Input Response Time | 40 ms maximum |
| Withstand Voltage | 2 kV AC between input signal and system for 1 minute |
| Environmental Protection | ISA Standard G3 compliant, Operating Temperature: -20°C to +70°C |
| Included Terminal Block | Pressure clamp terminal block for digital input without surge absorber (Model: STB4S-00) |
| Current Consumption | 290 mA maximum (5 V DC), 140 mA maximum (24 V DC) |
| Dimensions (W x H x D) | Approx. 32.8 mm x 130 mm x 120 mm |
| Weight | Approx. 0.38 kg |

FAQ
Q1: What does the suffix code “-S53” and option code “/B4S00” indicate on this module?
A: The -S denotes the standard module type, 5 specifies a pressure clamp terminal block connection with no explosion protection, 3 indicates ISA Standard G3 corrosive resistance with an extended operating temperature of -20°C to +70°C, and /B4S00 specifies the included STB4S-00 pressure clamp terminal block without a surge absorber.
Q2: Does the included STB4S-00 terminal block contain a surge absorber?
A: No, the /B4S00 option code supplies the STB4S-00 terminal block, which is designed without a built-in surge absorber.
Q3: Can the SDV144-S53 module be used for dual-redundant configurations?
A: For dual-redundant setups, a specific dual-redundant option code (such as /B4D00) and matching redundant hardware configuration should be selected according to system requirements.
Q4: What is the input response time of the digital input channels?
A: The maximum input response time for the 16 channels is 40 milliseconds, providing rapid signal acquisition for safety shutdown logic.
مستندات المنتج
فتح المستندات الفنية.
أدخل بريد العمل ورقم واتساب مرة واحدة للوصول إلى جميع المستندات.