المنتج
E+H Proline Prowirl F 200 Vortex Flowmeter
Proline Prowirl F 200 Vortex Flowmeter
The Endress+Hauser Prowirl F 200 is a versatile, high-precision vortex flowmeter engineered specifically for measuring steam, gases, and liquids in industrial utilities and energy management applications. Featuring integrated temperature and pressure compensation options and wet steam detection, it delivers reliable multi-variable measurement with long-term stability and zero pressure drop.
Advanced Vortex Flow Measurement for Steam, Gases, and Liquids
In modern industrial utility management, efficient steam distribution, compressed air monitoring, and gas accounting are critical for reducing energy waste and maintaining plant profitability. The Endress+Hauser Proline Prowirl F 200 Vortex Flowmeter represents a premier flow measurement solution designed specifically to meet international vortex standards (ISO 12764) while providing unmatched accuracy across demanding industrial processes. As an experienced global distributor of industrial automation and process control instruments, we supply authentic, brand-new Endress+Hauser field devices to support international plant engineering and maintenance projects.
The Prowirl F 200 operates on the Karman vortex street principle, where a bluff body generates alternating vortices proportional to fluid velocity. Supported by a robust, drift-free capacitive DSC sensor (Differential Switched Capacitance), the meter is exceptionally resistant to pipe vibrations, water hammer, and thermal shocks. Whether measuring saturated steam, superheated steam, compressed air, nitrogen, natural gas, or industrial water, the Prowirl F 200 delivers consistent, highly repeatable measurement accuracy.
Integrated Energy Management & Wet Steam Detection
Managing steam quality and energy consumption requires precise multi-variable data capture. The Prowirl F 200 can be configured with integrated temperature and pressure sensors, transforming a single inline flowmeter into a complete energy management station.
-
Integrated Temperature & Pressure Compensation: Automatically calculates corrected mass flow, standard volume flow, and heat energy flow for steam and gases without requiring external transmitters.
-
Wet Steam Detection (Optional): For DN 25 to 300 (1 to 12″) pipelines, the meter can detect wet steam conditions in real time, preventing energy billing errors and protecting downstream equipment from moisture damage.
-
Inlet Run Compensation: Built-in sensor algorithms compensate for restricted straight pipe inlet runs, saving valuable piping space on tight skids and congested utility headers.
Cost-Effective Two-Wire Loop-Powered Architecture
Traditionally, multi-variable vortex flowmeters required complex four-wire power systems or separate communication loops. The Prowirl F 200 features genuine two-wire 4-20 mA HART loop-powered technology, enabling seamless integration into existing control architectures while minimizing wiring complexity and installation costs.
The instrument is housed in a robust, dual-compartment aluminum or stainless steel enclosure rated for harsh industrial environments, ensuring long service life in outdoor utility yards or hazardous processing zones.
Embedded Diagnostics with Heartbeat Technology
To comply with strict ISO 9001 quality frameworks and internal safety requirements, the Prowirl F 200 integrates Endress+Hauser’s Heartbeat Technology. This onboard diagnostic and verification suite continuously monitors sensor health, electronics, and measuring performance in the background without interrupting active processes. Plant technicians can run automated verification checks on-demand and generate traceable verification reports for regulatory audits and preventive maintenance schedules.
Applications
-
Steam Generation & Distribution: Saturated and superheated steam monitoring, boiler efficiency testing, and steam energy accounting in power and manufacturing plants.
-
Compressed Air & Utility Networks: Totalization and leakage monitoring of compressed air, industrial gases (nitrogen, oxygen, CO2), and cooling water loops.
-
Chemical & Petrochemical Industry: Process gas and liquid utility metering where robust, drift-free long-term stability is required.
-
Food, Beverage & Life Sciences: Auxiliary steam loops, CIP utility water monitoring, and secondary plant utility management.
Technical Specifications
-
Measuring Principle: Vortex Flow Measurement (Karman Vortex Street)
-
Nominal Diameter Range: DN 15 to 300 (1/2″ to 12″)
-
Wetted Materials:
-
Measuring Tube: Stainless Steel 1.4408 (CF3M); Alloy C22 equivalent (2.4602)
-
DSC Sensor: Stainless Steel 1.4404 (316/316L); Alloy C22 equivalent (2.4602)
-
Process Connections: Stainless Steel 1.4404 (316/316L), Carbon Steel
-
-
Measured Variables: Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature, pressure
-
Max. Measurement Error:
-
Volume Flow (liquid): ±0.75 % of reading (Standard) or ±0.65 % (Optional)
-
Volume Flow (steam, gas): ±1.0 % of reading
-
Mass Flow (steam): ±1.5 % to ±1.7 % (compensated)
-
-
Measuring Range:
-
Liquid: 0.2 to 2100 m³/h (0.15 to 1520 ft³/min)
-
Steam & Gas: 1.5 to 28000 m³/h (0.9 to 16600 ft³/min)
-
-
Max. Process Pressure: PN 100, Class 600, 20K
-
Medium Temperature Range: -40 to +260 °C (-40 to +500 °F) standard; optional high/low temp version -200 to +400 °C (-328 to +752 °F)
-
Ambient Temperature Range: -40 to +80 °C (-40 to +176 °F)
-
Sensor & Transmitter Housing Material: Coated Die-cast Aluminum (AlSi10Mg) or Stainless Steel (1.4404 / 316L)
-
Degree of Protection: IP66/67, Type 4X enclosure
-
Display / Operation: 4-line backlit graphical display with optical touch control
-
Outputs / Communication: 4-20 mA HART, 4-20 mA analog, pulse/frequency/switch output, PROFIBUS PA, FOUNDATION Fieldbus, PROFINET over Ethernet-APL, Modbus TCP
-
Power Supply: DC 12 to 35 V (2-wire 4-20 mA HART loop-powered)
-
Hazardous Area Approvals: ATEX, IECEx, cCSAus, NEPSI, INMETRO, UK Ex
-
Safety & Quality Certifications: SIL 2/3, ISO 12764, CE, PED, CRN, NACE MR0175 / MR0103
FAQ
Q1: Is the Prowirl F 200 suitable for measuring wet steam? A1: Yes, for nominal diameters DN 25 to 300 (1 to 12″), the Prowirl F 200 offers an optional wet steam detection feature that identifies moisture content in steam lines to ensure accurate energy billing and protect equipment.
Q2: Is your company the original manufacturer of the Prowirl F 200? A2: No, we are an independent global distributor and supplier of industrial process automation instruments. We supply authentic, brand-new Endress+Hauser devices with full technical documentation, selection support, and global export services.
Q3: Can the Prowirl F 200 measure mass flow of steam directly? A3: Yes, by selecting the integrated temperature and pressure sensor options, the Prowirl F 200 calculates real-time compensated mass flow and energy flow for steam and gases without needing separate external transmitters.
Q4: How does Heartbeat Technology assist with maintenance? A4: Heartbeat Technology performs continuous, non-disruptive self-diagnostics and automated verification checks while the process is running, generating tamper-proof electronic reports for quality and safety audits.
مستندات المنتج
فتح المستندات الفنية.
أدخل بريد العمل ورقم واتساب مرة واحدة للوصول إلى جميع المستندات.