01Temperature MeasurementTemperature measurement uses temperature sensors, thermocouples, RTDs and other instruments to accurately detect and monitor process temperatures. 02Level MeasurementLevel measurement uses ultrasonic level meters, radar level meters, and other instruments to detect and monitor the level or height of materials in tanks, vessels, and process equipment. 03Pressure MeasurementPressure measurement uses pressure transmitters, differential pressure transmitters, and other instruments to detect and monitor pressure and pressure changes in pipelines, tanks, and process equipment. 04Flow measurementFlow measurement uses electromagnetic, ultrasonic, vortex, and mass flow meters to detect and monitor the flow of liquids, gases, or steam in pipelines. 05DCSYokogawa DCS cards are core modules of a distributed control system, used to acquire field signals such as temperature, pressure, and flow, while providing control, output, and communication functions. 06Water Quality AnalysisWater quality analysis uses water quality analyzers and online monitoring instruments to detect and monitor key parameters such as pH, dissolved oxygen, turbidity, conductivity, and residual chlorine in water. MODELE+H Proline Promass I 100 Coriolis FlowmeterDesigned for accurate multi-variable measurement of liquids and gases, this Coriolis flowmeter delivers simultaneous in-line viscosity, density, and mass flow data with minimal pressure loss. It features an ultra-compact transmitter and a robust single-tube titanium measuring system for demanding industrial processes. MODELYOKOGAWA A2EE3A-TN | ESB Bus Adapter Connector UnitThe YOKOGAWA A2EE3A-TN ESB Bus Adapter is engineered for Yokogawa CENTUM VP system architecture to connect and terminate the ESB bus at ANT522 optical repeater slave modules. Built for secure terminal connection and signal stability, this component ensures seamless communication extension across industrial automation networks. MODELE+H Levelflex FMP56 Guided Wave Radar Level TransmitterDesigned for continuous level measurement of powdery to granular bulk solids in tall silos and storage vessels, this cost-effective guided wave radar transmitter remains unaffected by heavy dust, filling noise, or thermal stratification. Featuring a high-tensile rope probe capable of withstanding pulling forces up to 12 kN, it integrates HistoROM data management and optional Bluetooth functionality for safe and efficient operation. MODELE+H Proline Promass X 300 Coriolis Mass FlowmeterThe Endress+Hauser Proline Promass X 300 is a maximum-capacity Coriolis mass flowmeter engineered for high-volume measurement of crude oil, refined hydrocarbons, chemicals, and industrial gases up to 4,100 t/h. Featuring a patented four-tube sensor system and integrated Heartbeat Technology, it offers exceptional operational efficiency, minimal pressure drop, and custody-transfer precision for large-scale energy and industrial processing applications. MODELChongqing Chuanyi MS22PSB2D10B0060DMZ Magnetostrictive Level GaugeEngineered for ultimate reliability and high-accuracy fluid monitoring, the MS Series Magnetostrictive Liquid Level Transmitter delivers continuous, real-time measurements for total liquid level and interface positions in demanding industrial environments. Utilizing advanced magnetostrictive sensing technology, this versatile transmitter provides precise, non-contact signal processing with a measurement accuracy up to ±1mm, making it an ideal solution for critical process controls across chemical processing, oil and gas, power generation, and water treatment applications where long-term stability and explosion-proof durability are paramount. MODELE+H FMU30 Non-Contact Ultrasonic Level TransmitterThe Prosonic FMU30 Non-Contact Ultrasonic Level Transmitter provides highly accurate, maintenance-free continuous level and open-channel flow measurement for liquids, pastes, and coarse bulk solids across municipal and industrial applications. Featuring an integrated temperature sensor for automatic sound velocity compensation, a user-friendly 4-line plain text display with 32-point linearization, and a rugged IP68-rated weatherproof enclosure, this compact 2-wire transmitter delivers dependable real-time tank monitoring, pump control, and overflow protection in sewage treatment plants, process water storage, and chemical buffer tanks. MODELE+H Deltabar PMD55B High Precision Smart Differential Pressure TransmitterThe PMD55B High Precision Smart Differential Pressure Transmitter delivers exceptionally accurate differential pressure, flow, and hydrostatic level measurements for industrial liquids, gases, and steam. Featuring a robust metallic diaphragm, ultra-low long-term drift, optional wireless Bluetooth operation, and SIL2/3 functional safety certifications, this versatile instrument provides stable, error-free process monitoring across harsh chemical, oil, and water treatment environments. MODELE+H Waterpilot FMX11 Submersible Hydrostatic Level TransmitterThe Waterpilot FMX11 is a high-precision, heavy-duty submersible hydrostatic level transmitter engineered for continuous liquid level and depth monitoring in fresh water, groundwater wells, drinking water reservoirs, and surface water bodies. Featuring an ultra-compact 22mm stainless steel 316L housing, an integrated atmospheric pressure compensation tube with a protective Teflon filter, and international drinking water certifications, this compact dip cell sensor delivers exceptional long-term stability and precise 4–20 mA signal output even in narrow 1-inch pipes and demanding environmental conditions. MODELChongqing Chuanyi WZGPK-73DH-GB/1P2-AJ150G-M20XC6-AXX-I5/2AM20 Explosion-proof RTDThe WZGPK is a heavy-duty explosion-proof armored Pt100 RTD temperature sensor engineered for accurate thermal monitoring in hazardous industrial environments. Equipped with a high-precision Class A platinum sensing element, a 3-wire connection, a 6mm diameter sheath made of durable 321 stainless steel, and a 150mm insertion length, this flameproof sensor delivers exceptionally fast thermal response, vibration resistance, and long-term stability across a wide temperature range from -200°C to 600°C. Designed with an M20x1.5 process thread and an explosion-proof junction box, it provides reliable flameproof protection and continuous signal accuracy for chemical plants, oil refineries, and automated process control systems. MODELYokogawa ADV151-P50/D5A00 Digital Input Module ExstockEngineered for reliable industrial automation, the Yokogawa ADV151-P50/D5A00 Digital Input Module provides high-density 32-channel, 24 V DC isolated signal processing alongside dedicated connection adapters, ensuring optimal signal integrity, robust noise immunity, and seamless integration into distributed control systems (DCS). MODELYokogawa AAI143-H50 Analog Input Module ExstockThe Yokogawa AAI143-H50 is a high-performance 16-channel isolated analog input module designed for process automation systems, capable of handling 4 to 20 mA standard signal inputs with exceptional stability and accuracy. Supplied with its matching terminal block adapter, this module offers seamless integration, superior noise immunity, and reliable data acquisition for demanding industrial environments. MODELYokogawa S2CP471-01 Controller Module Spare Part ExstockThe Yokogawa S2CP471-01 Controller Module Spare Part provides reliable, real-time control performance and high-speed VNET/IP communication connectivity to optimize your industrial DCS automation system with seamless integration and reduced operational downtime. SOLUTIONSmart water network monitoringCombine verified flow and pressure data for distribution monitoring and operational review. SOLUTIONHydrogen pressure measurementReview materials, pressure range and safety requirements for hydrogen process measurement. SOLUTIONProcess measurement selectionStart from the medium, operating window, installation and required signal before selecting an instrument.

Yokogawa VY Series Vortex Flowmeter

VY

The Yokogawa VY Series Vortex Flowmeter is engineered for accurate liquid, gas, and steam flow measurement across industrial applications. It features advanced digital communication compatibility and a robust, obstructionless design tailored for continuous, reliable operation.

industrial vortex flowmeter for liquid gas and steam measurement

Product Overview

The Yokogawa VY Series Vortex Flowmeter stands at the forefront of industrial process measurement, delivering exceptional accuracy and long-term stability for monitoring diverse fluid types. Designed to meet the rigorous demands of modern industrial automation, this digital gas flowmeter and liquid monitoring device integrates cutting-edge frequency output technology with a rugged mechanical structure. Whether deployed in chemical processing plants, power generation, or general utility networks, this industrial vortex meter ensures precise data acquisition and seamless system integration.

Core Technology & Measurement Principle

Operating on the principle of Karman vortex shedding, the Yokogawa VY vortex flowmeter measures the frequency of vortices generated behind a precision-engineered shedder bar. With no internal moving parts, this obstructionless design completely eliminates pressure drops and significantly reduces maintenance requirements. The device features an intuitive local indicator equipped with high-visibility displays, alarm icons, and interactive setting switches, enabling engineers to monitor process variables and configure parameters safely.

Communication & System Flexibility

Equipped with versatile communication protocols—including HART protocol, FOUNDATION Fieldbus, and Modbus communication types—the VY series flow meter offers flexible integration into existing control room architectures. It supports active 4 to 20 mA analog outputs, pulse outputs, status alarms, and auxiliary analog inputs, ensuring comprehensive feedback for complex control loops. Furthermore, data backup and restoration are fully supported via pre-amplifier data storage, enhancing operational efficiency during maintenance.

Rugged Build & Safety Standards

Built to withstand harsh industrial environments, the flowmeter complies with strict international EMC standards and offers waterproof construction options (IP66/IP67 / Type 4X). The meter incorporates rigorous grounding options, lightning protection capabilities (option code /A), and robust temperature ranges, ensuring maximum structural integrity and safety in demanding outdoor or indoor installations.

Application Fields

  • Chemical & Petrochemical Processing: Ensures stable, high-precision flow monitoring for corrosive and high-temperature chemical media within industrial piping networks.

  • Power & Steam Generation: Accurately measures superheated and saturated steam flows to optimize thermal energy efficiency and boiler performance.

  • Water & Wastewater Management: Delivers reliable continuous flow measurement for municipal and industrial water distribution and effluent treatment.

  • Industrial Manufacturing & Process Automation: Integrates seamlessly with DCS and PLC architectures via HART, Fieldbus, or Modbus for real-time liquid, gas, and steam tracking.

Technical Specifications

  • Applicable Fluids: Liquid, Gas, and Steam

  • Size Range: 15 mm to 400 mm (0.5 in. to 16 in.)

  • Communication Protocols: HART (HART 7), FOUNDATION Fieldbus, and Modbus (RS-485)

  • Power Supply Voltage:

    • HART Type: 10.5 to 42 V DC (10.5 to 30 V DC with lightning protector)

    • Fieldbus / Modbus Type: 9 to 32 V DC / 9 to 30 V DC

  • Output Signals: 4 to 20 mA DC analog output, pulse output (80 mA DC max), and status/alarm contacts

  • Enclosure Protection: IP66 / IP67 (IEC 60529) and NEMA Type 4X

  • Ambient Temperature Range: -29°C to 85°C (Standard type); options available down to -50°C (/LAT)

FAQ

  • Q: Can the VY Series flowmeter measure multi-phase flows such as gas-liquid mixtures?

    • A: No. While the flowmeter handles liquid, gas, and steam independently within the same structure, accurate measurement of mixed multi-phase flows (such as bubble or mist flows) is not possible.

  • Q: How is zero adjustment performed if the meter outputs a signal during zero flow?

    • A: Although zero drift is minimal due to the frequency output sensor, you can perform manual low-cut adjustments or execute “Tuning at zero” (Zero Tuning) via the configuration tool or indicator when the fluid flow is completely stopped.

  • Q: What should be checked if the indication drops to zero while fluid is flowing?

    • A: Check for potential coating or scaling on the vortex shedder bar or inner tube, verify that parameter configurations match operating conditions, and ensure the low-cut or TLA values are correctly set.

Unlock technical documents.

Enter your work email and WhatsApp number once to access all documents for this product.