Search products

Search by technology, medium or application.

01Temperature MeasurementTemperature measurement uses temperature sensors, thermocouples, RTDs and other instruments to accurately detect and monitor process temperatures. 02Level MeasurementLevel measurement uses ultrasonic level meters, radar level meters, and other instruments to detect and monitor the level or height of materials in tanks, vessels, and process equipment. 03Pressure MeasurementPressure measurement uses pressure transmitters, differential pressure transmitters, and other instruments to detect and monitor pressure and pressure changes in pipelines, tanks, and process equipment. 04Flow measurementFlow measurement uses electromagnetic, ultrasonic, vortex, and mass flow meters to detect and monitor the flow of liquids, gases, or steam in pipelines. 05DCSYokogawa DCS cards are core modules of a distributed control system, used to acquire field signals such as temperature, pressure, and flow, while providing control, output, and communication functions. 06Water Quality AnalysisWater quality analysis uses water quality analyzers and online monitoring instruments to detect and monitor key parameters such as pH, dissolved oxygen, turbidity, conductivity, and residual chlorine in water. MODELE+H Proline Promass I 100 Coriolis FlowmeterDesigned for accurate multi-variable measurement of liquids and gases, this Coriolis flowmeter delivers simultaneous in-line viscosity, density, and mass flow data with minimal pressure loss. It features an ultra-compact transmitter and a robust single-tube titanium measuring system for demanding industrial processes. MODELYOKOGAWA A2EE3A-TN | ESB Bus Adapter Connector UnitThe YOKOGAWA A2EE3A-TN ESB Bus Adapter is engineered for Yokogawa CENTUM VP system architecture to connect and terminate the ESB bus at ANT522 optical repeater slave modules. Built for secure terminal connection and signal stability, this component ensures seamless communication extension across industrial automation networks. MODELE+H Levelflex FMP56 Guided Wave Radar Level TransmitterDesigned for continuous level measurement of powdery to granular bulk solids in tall silos and storage vessels, this cost-effective guided wave radar transmitter remains unaffected by heavy dust, filling noise, or thermal stratification. Featuring a high-tensile rope probe capable of withstanding pulling forces up to 12 kN, it integrates HistoROM data management and optional Bluetooth functionality for safe and efficient operation. MODELE+H Proline Promass X 300 Coriolis Mass FlowmeterThe Endress+Hauser Proline Promass X 300 is a maximum-capacity Coriolis mass flowmeter engineered for high-volume measurement of crude oil, refined hydrocarbons, chemicals, and industrial gases up to 4,100 t/h. Featuring a patented four-tube sensor system and integrated Heartbeat Technology, it offers exceptional operational efficiency, minimal pressure drop, and custody-transfer precision for large-scale energy and industrial processing applications. MODELChongqing Chuanyi MS22PSB2D10B0060DMZ Magnetostrictive Level GaugeEngineered for ultimate reliability and high-accuracy fluid monitoring, the MS Series Magnetostrictive Liquid Level Transmitter delivers continuous, real-time measurements for total liquid level and interface positions in demanding industrial environments. Utilizing advanced magnetostrictive sensing technology, this versatile transmitter provides precise, non-contact signal processing with a measurement accuracy up to ±1mm, making it an ideal solution for critical process controls across chemical processing, oil and gas, power generation, and water treatment applications where long-term stability and explosion-proof durability are paramount. MODELE+H FMU30 Non-Contact Ultrasonic Level TransmitterThe Prosonic FMU30 Non-Contact Ultrasonic Level Transmitter provides highly accurate, maintenance-free continuous level and open-channel flow measurement for liquids, pastes, and coarse bulk solids across municipal and industrial applications. Featuring an integrated temperature sensor for automatic sound velocity compensation, a user-friendly 4-line plain text display with 32-point linearization, and a rugged IP68-rated weatherproof enclosure, this compact 2-wire transmitter delivers dependable real-time tank monitoring, pump control, and overflow protection in sewage treatment plants, process water storage, and chemical buffer tanks. MODELE+H Deltabar PMD55B High Precision Smart Differential Pressure TransmitterThe PMD55B High Precision Smart Differential Pressure Transmitter delivers exceptionally accurate differential pressure, flow, and hydrostatic level measurements for industrial liquids, gases, and steam. Featuring a robust metallic diaphragm, ultra-low long-term drift, optional wireless Bluetooth operation, and SIL2/3 functional safety certifications, this versatile instrument provides stable, error-free process monitoring across harsh chemical, oil, and water treatment environments. MODELE+H Waterpilot FMX11 Submersible Hydrostatic Level TransmitterThe Waterpilot FMX11 is a high-precision, heavy-duty submersible hydrostatic level transmitter engineered for continuous liquid level and depth monitoring in fresh water, groundwater wells, drinking water reservoirs, and surface water bodies. Featuring an ultra-compact 22mm stainless steel 316L housing, an integrated atmospheric pressure compensation tube with a protective Teflon filter, and international drinking water certifications, this compact dip cell sensor delivers exceptional long-term stability and precise 4–20 mA signal output even in narrow 1-inch pipes and demanding environmental conditions. MODELChongqing Chuanyi WZGPK-73DH-GB/1P2-AJ150G-M20XC6-AXX-I5/2AM20 Explosion-proof RTDThe WZGPK is a heavy-duty explosion-proof armored Pt100 RTD temperature sensor engineered for accurate thermal monitoring in hazardous industrial environments. Equipped with a high-precision Class A platinum sensing element, a 3-wire connection, a 6mm diameter sheath made of durable 321 stainless steel, and a 150mm insertion length, this flameproof sensor delivers exceptionally fast thermal response, vibration resistance, and long-term stability across a wide temperature range from -200°C to 600°C. Designed with an M20x1.5 process thread and an explosion-proof junction box, it provides reliable flameproof protection and continuous signal accuracy for chemical plants, oil refineries, and automated process control systems. MODELYokogawa ADV151-P50/D5A00 Digital Input Module ExstockEngineered for reliable industrial automation, the Yokogawa ADV151-P50/D5A00 Digital Input Module provides high-density 32-channel, 24 V DC isolated signal processing alongside dedicated connection adapters, ensuring optimal signal integrity, robust noise immunity, and seamless integration into distributed control systems (DCS). MODELYokogawa AAI143-H50 Analog Input Module ExstockThe Yokogawa AAI143-H50 is a high-performance 16-channel isolated analog input module designed for process automation systems, capable of handling 4 to 20 mA standard signal inputs with exceptional stability and accuracy. Supplied with its matching terminal block adapter, this module offers seamless integration, superior noise immunity, and reliable data acquisition for demanding industrial environments. MODELYokogawa S2CP471-01 Controller Module Spare Part ExstockThe Yokogawa S2CP471-01 Controller Module Spare Part provides reliable, real-time control performance and high-speed VNET/IP communication connectivity to optimize your industrial DCS automation system with seamless integration and reduced operational downtime. SOLUTIONSmart water network monitoringCombine verified flow and pressure data for distribution monitoring and operational review. SOLUTIONHydrogen pressure measurementReview materials, pressure range and safety requirements for hydrogen process measurement. SOLUTIONProcess measurement selectionStart from the medium, operating window, installation and required signal before selecting an instrument.

Yokogawa | ALF111-S50/F9S00 FOUNDATION Fieldbus Communication Module

ALF111-S50/F9S00

The Yokogawa ALF111-S50/F9S00 FOUNDATION fieldbus communication module provides reliable H1 digital bus connectivity between Yokogawa CENTUM distributed control systems and intelligent field devices. Equipped with dual fieldbus ports, bus power supply support, and modular redundancy features, this 0.3 kg interface card ensures robust data acquisition and multi-variable instrument integration. Request current stock and pricing today for genuine Yokogawa hardware.

Yokogawa ALF111-S50 F9S00 FOUNDATION fieldbus communication module

Advanced Fieldbus Integration for Modern DCS Architectures

In contemporary process automation facilities—such as chemical plants, oil refineries, and power generation stations—transitioning from traditional analog signals to fully digital fieldbus communication is essential for advanced diagnostics and multi-variable data collection. The Yokogawa ALF111-S50/F9S00 FOUNDATION Fieldbus Communication Module serves as a core master interface within Yokogawa CENTUM VP Field Control Stations (FCS). By connecting directly to FOUNDATION fieldbus H1 loops, the module allows control engineers to integrate transmitters, flowmeters, and actuators directly into the control function blocks.

H1 Bus Communication and Power Distribution

The ALF111-S50/F9S00 module supports standard FOUNDATION fieldbus H1 communication operating at a transmission speed of 31.25 kbps using Manchester II bi-phase encoding. The module facilitates bidirectional digital communication and supplies field bus power to connected instruments through approved power distribution components. Each module supports multiple fieldbus devices per port, enabling comprehensive device management, block transfers, and real-time alarm reporting directly within the CENTUM VP engineering environment.

Dual-Redundancy and Rugged Industrial Specifications

Designed for continuous 24/7 mission-critical operations, the ALF111-S50/F9S00 supports communication path dual-redundancy when two identical modules are paired in adjacent even and odd slots of a node unit. Front-panel LED indicators offer real-time visual diagnostics for module health, communication activity, and power status. With a net weight of approximately 0.3 kg and a low current consumption of 0.5 A, the module installs securely into standard Field Control Units and ESB bus node racks.

Applications

  • Distributed Control Systems (DCS): FOUNDATION fieldbus H1 integration within Yokogawa CENTUM VP control station architectures.

  • Oil & Gas Refineries: Digital multi-variable transmitter data collection and smart valve diagnostics on upstream and downstream units.

  • Chemical & Petrochemical Plants: Bus-powered instrument integration for complex reaction skids and hazardous area monitoring.

  • Power Generation Facilities: Centralized monitoring of digital field devices, smart actuators, and auxiliary control loops.

  • Water & Wastewater Treatment: Advanced digital telemetry and instrument management across extended plant networks.

Technical Specifications

  • Manufacturer: Yokogawa

  • Product Model: ALF111-S50/F9S00

  • Product Type: FOUNDATION Fieldbus Communication Module (H1)

  • Communication Protocol: FOUNDATION fieldbus H1

  • Transmission Speed: 31.25 kbps

  • Physical Layer Standard: IEC 61158-2

  • Number of Ports: 2 ports (H1 bus connection)

  • Dual-Redundancy: Supported (paired in adjacent even/odd slots)

  • Current Consumption: 0.5 A

  • Module Net Weight: Approx. 0.3 kg

  • Compatible Control Units: AFV30, AFV40, AFV10, AFF50, ANB10, ANB11, ANR10 series

FAQ

Q1: What is the primary function of the Yokogawa ALF111-S50/F9S00 module? A: The ALF111-S50/F9S00 is a FOUNDATION fieldbus H1 communication module that connects Yokogawa CENTUM VP control systems to digital field instruments and smart transmitters.

Q2: What is the communication transmission speed of the ALF111 module? A: In accordance with FOUNDATION fieldbus H1 standards, the module operates at a transmission speed of 31.25 kbps using IEC 61158-2 physical layers.

Q3: Can the ALF111-S50/F9S00 be configured for dual-redundant operation? A: Yes. Dual-redundant communication is supported by installing two identical ALF111 modules in adjacent even and odd-numbered slots on the same node unit.

Q4: How can I confirm pricing and lead time for this part? A: Simply submit your required model code and quantity through our website inquiry form to receive a prompt quotation.

Unlock technical documents.

Enter your work email and WhatsApp number once to access all documents for this product.

By submitting, you agree that FUGUI may contact you about this product. Your details are stored privately for sales follow-up.